Motor Sizing Calculator

Use this motor sizing calculator to estimate required motor horsepower or kilowatts from mechanical torque, rotational speed, efficiency, and an appropriate ser

Motor Sizing Calculator Tool

Enter your values in the calculator above, then use the explanations below to understand the result, check assumptions, and compare scenarios.

About this calculator

Use this motor sizing calculator to estimate required motor horsepower or kilowatts from mechanical torque, rotational speed, efficiency, and an appropriate service factor or design margin. It supports preliminary electric motor sizing for rotating machinery such as pumps, fans, conveyors, mixers, and driven equipment. Final motor selection should also account for starting torque, acceleration, duty cycle, enclosure, ambient conditions, controls, and the driven machine's load profile.

Rotating mechanical power is determined by torque and speed. In U.S. customary units, horsepower can be estimated from torque in lb-ft and rotational speed in RPM using HP = torque × RPM ÷ 5252. Metric calculations use the equivalent torque-speed power relationship to determine watts or kilowatts. If the required mechanical output is known, motor input and selection also depend on efficiency and the design margin needed for the application.

Select the next appropriate standard motor rating above the calculated requirement after considering the actual load profile. A motor that meets steady-state horsepower may still be unsuitable if the application has high breakaway torque, frequent starts, rapid acceleration, cyclic loading, high ambient temperature, altitude, or a demanding duty cycle. Variable-frequency-drive applications also require motor and drive compatibility checks, particularly at low speed and for insulation, cooling, and overload performance.

Worked examples

Torque-based motor sizing

A machine requires 20 lb-ft of shaft torque at 1,750 RPM.

  1. Use HP = torque × RPM ÷ 5252
  2. Multiply 20 by 1,750
  3. Divide by 5,252

Result: Required shaft power is about 6.66 HP before efficiency and design margin are considered.

Selecting the next standard motor size

A calculation produces a required motor output above a common standard rating.

  1. Calculate the mechanical power requirement
  2. Apply the application's design or service margin
  3. Select an available motor rating that meets or exceeds the resulting requirement

Result: Do not round down when doing so would leave the motor below the required continuous mechanical load.

Motor sizing for a variable load

A conveyor has higher torque during startup than during normal running.

  1. Determine both running torque and breakaway or acceleration torque
  2. Check the required starting and accelerating performance
  3. Verify the motor and starter or VFD can supply the required torque without exceeding limits

Result: Steady-state horsepower alone is not enough to validate a high-starting-torque application.

Practical tips

  • Use load torque at the motor shaft after accounting for gearing or transmission ratio.
  • Verify both steady-state power and startup or acceleration torque.
  • Use manufacturer efficiency data when available rather than a generic assumption.
  • Check duty cycle, ambient temperature, altitude, enclosure, and cooling requirements.
  • For VFD applications, confirm the motor's allowable speed range and torque capability.

Common mistakes

  • Sizing from horsepower alone while ignoring required torque at operating speed.
  • Confusing motor shaft output power with electrical input power.
  • Ignoring startup, breakaway, or acceleration torque.
  • Applying an arbitrary oversized service factor without understanding the driven load.
  • Assuming a motor can deliver rated torque continuously at any VFD speed without cooling or thermal limitations.

Torque and speed examples using HP = torque × RPM ÷ 5252

TorqueSpeedApprox. shaft power
10 lb-ft1,750 RPM3.33 HP
20 lb-ft1,750 RPM6.66 HP
30 lb-ft1,750 RPM10.0 HP
20 lb-ft3,500 RPM13.33 HP

Key terms

Torque
Rotational force acting about a shaft, commonly expressed in lb-ft or N·m.
RPM
Revolutions per minute, a measure of rotational speed.
Horsepower
A unit of mechanical power commonly used for motor ratings in the United States.
Service factor
A nameplate factor describing allowable loading above rated horsepower under specified conditions.
Breakaway torque
Torque required to begin moving a stationary driven load.

Frequently asked questions

How do I calculate motor horsepower from torque and RPM?
For torque in lb-ft, use HP = torque × RPM ÷ 5252. For example, 10 lb-ft at 1,750 RPM is approximately 3.33 HP of mechanical shaft power.
Should I choose the exact calculated motor horsepower?
Not necessarily. Compare the calculated requirement with available standard motor ratings and account for the application's duty, startup torque, acceleration, service factor, environment, and manufacturer recommendations.
Can this calculator size a three-phase motor?
It can estimate the mechanical power requirement independent of phase. Electrical current, conductor, starter, overload, and protection calculations require the motor's voltage, efficiency, power factor, nameplate data, and applicable electrical rules.
How does efficiency affect motor sizing?
Efficiency relates electrical input power to mechanical shaft output. A motor must draw more electrical power than it delivers mechanically because some input energy is lost as heat and other losses.
What is service factor in motor sizing?
Service factor is a motor nameplate characteristic describing permitted operation above rated load under specified conditions. It should not be treated as a universal substitute for proper load, thermal, duty-cycle, and starting analysis.
Can I use this for a pump or fan motor?
Yes for preliminary power sizing when the required shaft torque or power is known. Pump and fan applications should also use the equipment performance curve, operating point, starting conditions, and expected range of system resistance.